Fire Alarm System Inspection & Testing

Annual or semiannual NFPA 72 inspection and testing, including panel function test, battery check, and communicator verification.

We inspect and test the fire alarm control panel, power supplies, initiating and notification devices, and monitoring path so your system is documented and ready for the AHJ.

What this service covers

  • Panel, power, and battery verification
  • Initiating and notification device testing
  • Monitoring station signal confirmation
  • NFPA 72 certificate with device inventory

Questions

Fire Alarms — frequently asked

Do fire alarm companies need a Texas state license?

Yes. A company must hold a Fire Alarm Certificate of Registration (ACR) from the Texas SFMO, and each technician who installs, services, or monitors alarm systems must hold the matching individual fire alarm license.

How often does Texas require a commercial fire alarm system to be tested?

NFPA 72, the SFMO's adopted minimum standard, calls for a full functional test at least once a year, with a semiannual visual inspection of initiating devices. Some device types, like waterflow switches, test quarterly, and your local AHJ can require more.

Does the annual fire alarm test cover the monitoring connection?

Yes. A proper NFPA 72 test verifies that the communicator actually reaches the central monitoring station, not just that the panel and devices function locally.

How long do fire alarm inspection records need to be kept?

Licensed companies keep inspection and test records and make them available to the property owner and the local AHJ; three years is a commonly cited minimum, though a specific jurisdiction may ask for longer.

See all frequently asked questions

Inspection checklist

What we check on every visit

This is the same point-by-point checklist that appears on your AHJ-ready report.

46

Point checklist

NFPA 72 · Full system · Annual

AHJ-ready PDF

Panel, devices, monitoring, and controls verified — certified for the AHJ.

System information

  • Panel tag confirmed
  • Manufacturer & model
  • Zones / SLC loops
  • Monitoring company & account
  • Communication path type

Panel & power

  • Panel normal; cabinet secure
  • Fuses, breakers & LEDs OK
  • AC power & secondary transfer
  • Battery standby / alarm test
  • Event log functional
  • Trouble / supervisory display
  • Annunciator & backup path
  • Ground-fault isolation test
  • Charger output in spec

Devices, monitoring & controls

  • Initiating device alarm at panel
  • Horns / strobes activate
  • NAC open / short supervision
  • 100% test or AHJ rotation plan
  • Devices clean & in range
  • Alarm received at monitoring
  • Supervisory / trouble at station
  • HVAC, dampers, doors, elevator
  • Relay / shunt outputs verified