Fire Alarm System Inspection & Testing Annual or semiannual NFPA 72 inspection and testing, including panel function test, battery check, and communicator verification.
We inspect and test the fire alarm control panel, power supplies, initiating and notification devices, and monitoring path so your system is documented and ready for the AHJ.
What this service covers Panel, power, and battery verification Initiating and notification device testing Monitoring station signal confirmation NFPA 72 certificate with device inventory Questions
Fire Alarms — frequently asked Do fire alarm companies need a Texas state license? Yes. A company must hold a Fire Alarm Certificate of Registration (ACR) from the Texas SFMO, and each technician who installs, services, or monitors alarm systems must hold the matching individual fire alarm license.
How often does Texas require a commercial fire alarm system to be tested? NFPA 72, the SFMO's adopted minimum standard, calls for a full functional test at least once a year, with a semiannual visual inspection of initiating devices. Some device types, like waterflow switches, test quarterly, and your local AHJ can require more.
Does the annual fire alarm test cover the monitoring connection? Yes. A proper NFPA 72 test verifies that the communicator actually reaches the central monitoring station, not just that the panel and devices function locally.
How long do fire alarm inspection records need to be kept? Licensed companies keep inspection and test records and make them available to the property owner and the local AHJ; three years is a commonly cited minimum, though a specific jurisdiction may ask for longer.
See all frequently asked questions
Inspection checklist
What we check on every visit This is the same point-by-point checklist that appears on your AHJ-ready report.
46
Point checklist
NFPA 72 · Full system · Annual
AHJ-ready PDF Panel, devices, monitoring, and controls verified — certified for the AHJ.
System information
Panel tag confirmed Manufacturer & model Zones / SLC loops Monitoring company & account Communication path type Panel & power
Panel normal; cabinet secure Fuses, breakers & LEDs OK AC power & secondary transfer Battery standby / alarm test Event log functional Trouble / supervisory display Annunciator & backup path Ground-fault isolation test Charger output in spec Devices, monitoring & controls
Initiating device alarm at panel Horns / strobes activate NAC open / short supervision 100% test or AHJ rotation plan Devices clean & in range Alarm received at monitoring Supervisory / trouble at station HVAC, dampers, doors, elevator Relay / shunt outputs verified Related Reading
From the blog Ready to schedule fire alarms? Tell us about your site and we'll follow up with availability and pricing.
Get a Quote Fortress Fire Protection
NFPA-compliant inspection, testing and maintenance for commercial properties across the Fort Worth metro — extinguishers, fire alarm, and emergency lighting, with the documentation your AHJ asks for.
Request a Quote Check your coverage © 2026 Fortress Fire Protection. All rights reserved.
ECR-3530956 · ACR-3532428
Fire Alarm System Inspection & Testing
Annual or semiannual NFPA 72 inspection and testing, including panel function test, battery check, and communicator verification.
Fortress Fire Protection — Boyd, TX 76023 · Phone: +1-817-527-9900 · Email: info@fortressfireprotection.org · Texas firm registrations: ECR-3530956 · ACR-3532428
Fire Alarm System Inspection & Testing — frequently asked
Do fire alarm companies need a Texas state license?
Yes. A company must hold a Fire Alarm Certificate of Registration (ACR) from the Texas SFMO, and each technician who installs, services, or monitors alarm systems must hold the matching individual fire alarm license.
How often does Texas require a commercial fire alarm system to be tested?
NFPA 72, the SFMO's adopted minimum standard, calls for a full functional test at least once a year, with a semiannual visual inspection of initiating devices. Some device types, like waterflow switches, test quarterly, and your local AHJ can require more.
Does the annual fire alarm test cover the monitoring connection?
Yes. A proper NFPA 72 test verifies that the communicator actually reaches the central monitoring station, not just that the panel and devices function locally.
How long do fire alarm inspection records need to be kept?
Licensed companies keep inspection and test records and make them available to the property owner and the local AHJ; three years is a commonly cited minimum, though a specific jurisdiction may ask for longer.
From the blog
Services
Service areas
Fire protection in Arlington, TX Fire protection in Azle, TX Fire protection in Bedford, TX Fire protection in Benbrook, TX Fire protection in Blue Mound, TX Fire protection in Boyd, TX Fire protection in Carrollton, TX Fire protection in Coppell, TX Fire protection in Crowley, TX Fire protection in Dallas, TX Fire protection in Decatur, TX Fire protection in Denton, TX Fire protection in Euless, TX Fire protection in Everman, TX Fire protection in Flower Mound, TX Fire protection in Fort Worth, TX Fire protection in Grand Prairie, TX Fire protection in Grapevine, TX Fire protection in Haltom City, TX Fire protection in Haslet, TX Fire protection in Hurst, TX Fire protection in Irving, TX Fire protection in Lake Worth, TX Fire protection in Richland Hills, TX Fire protection in River Oaks, TX Fire protection in Roanoke, TX Fire protection in Saginaw, TX Fire protection in Sansom Park, TX Fire protection in Springtown, TX Fire protection in Watauga, TX Fire protection in Weatherford, TX Fire protection in Westworth Village, TX Fire protection in White Settlement, TX