NFPA 10

Fire Extinguisher Inspection & Tagging

Annual NFPA 10 inspection, tagging, and documentation for every extinguisher on your property, with a deficiency report if anything needs attention.

We inspect each portable extinguisher on site — accessibility, condition, pressure, weight, and service history — then apply a current annual tag and deliver an AHJ-ready report.

What this service covers

  • Per-unit annual inspection to NFPA 10 §7.2.2
  • Service tags applied when units pass
  • Deficiency notes with practical next steps
  • Digital certificate and inventory summary

Questions

Extinguisher Inspection — frequently asked

How often do fire extinguishers need to be inspected?

Most commercial fire extinguishers need a documented annual inspection, along with regular visual checks by the facility. Service needs can vary by equipment type, condition, and local requirements.

What happens if an extinguisher does not pass inspection?

The issue is documented as a deficiency. Depending on the condition, the next step may be repair, recharge, 6-year maintenance, hydrostatic testing, replacement, or relocating the unit so it is accessible.

Can you replace an extinguisher during service?

When inventory and site authorization allow, replacement can be handled during the visit. If not, replacement can be quoted and scheduled as follow-up work.

Do fire extinguisher companies have to be licensed in Texas?

Yes. Any company that sells, installs, or services fire extinguishers in Texas must hold a Fire Extinguisher Certificate of Registration (ECR) from the Texas Department of Insurance's State Fire Marshal's Office, and every technician performing the work must hold an individual state extinguisher license.

See all frequently asked questions

Inspection checklist

What we check on every visit

This is the same point-by-point checklist that appears on your AHJ-ready report.

33

Point checklist

NFPA 10 · Per extinguisher · Annual

AHJ-ready PDF

Every unit tagged, pressure-checked, and certified in one AHJ-ready PDF.

Unit identification

  • Asset tag / barcode confirmed
  • Manufacturer & model recorded
  • Serial number & manufacture date
  • Agent type, capacity & rating
  • Building, floor & location

Physical condition

  • Accessible and not obstructed
  • Mounted correctly and visible
  • Operating instructions face out
  • Shell free of dents / corrosion
  • Safety pin & tamper seal intact
  • Nozzle / hose clear and undamaged
  • Label legible with correct agent

Gauge, weight & service

  • Gauge needle in green range
  • Gauge undamaged
  • Actual PSI recorded
  • Weight within label range
  • Recorded weight (lbs)
  • Prior annual tag present
  • Hydro & 6-year dates logged
  • New annual tag + tech initials

Ready to schedule extinguisher inspection?

Tell us about your site and we'll follow up with availability and pricing.